Study of optical absorbance and MR relaxation of Fricke XYLENOL ORANGE (cas 1611-35-4) gel dosimeters
-
Add time:07/25/2019 Source:sciencedirect.com
Studies on the optical absorbance spectra of Fricke XYLENOL ORANGE (cas 1611-35-4) gel dosimeters were performed, in the wavelength range from 300 nm to 800 nm, in order to highlight some particular characteristics that can affect the achievable precision. The spectra are different mainly due to the different types of xylenol orange that was used and to a lower extent due to the different gelling agents (agarose or gelatine). The characteristic of variation of absorbance spectra versus dose, however, are similar in the various cases and can explain some peculiarities, as apparent effects of dose threshold. Changes of spectral shapes appear over the time after irradiation. Magnetic resonance measurements performed at various times after irradiation only reveal the slow changes due to the auto-oxidation effect, proving therefore that the modality of chelation of ferric ions by xylenol orange can affect the observed changes in the optical absorbance spectra.
We also recommend Trading Suppliers and Manufacturers of XYLENOL ORANGE (cas 1611-35-4). Pls Click Website Link as below: cas 1611-35-4 suppliers
Prev:Fricke-gel dosimeter: overview of XYLENOL ORANGE (cas 1611-35-4) chemical behavior
Next:Spectroscopic studies of interaction between XYLENOL ORANGE (cas 1611-35-4) and cationic surfactant in aqueous solution) - 【Back】【Close 】【Print】【Add to favorite 】
- Related Information
- Reuse of sustainable materials for XYLENOL ORANGE (cas 1611-35-4) dye and copper (II) ion ammoniacal removal07/28/2019
- Bi-porous bioinspired chitosan foams with layered structure and their adsorption for XYLENOL ORANGE (cas 1611-35-4)07/27/2019
- Spectroscopic studies of interaction between XYLENOL ORANGE (cas 1611-35-4) and cationic surfactant in aqueous solution07/26/2019
- Fricke-gel dosimeter: overview of XYLENOL ORANGE (cas 1611-35-4) chemical behavior07/24/2019
- XYLENOL ORANGE (cas 1611-35-4) functionalised polymers to overcome diffusion in Fricke gel radiation dosimeters07/23/2019
- Colorimetric detection of scale drop disease virus in Asian sea bass using loop-mediated isothermal amplification with XYLENOL ORANGE (cas 1611-35-4)07/22/2019
- Study of the effect of laponite on Fricke XYLENOL ORANGE (cas 1611-35-4) gel dosimeter by optical techniques07/20/2019
- XYLENOL ORANGE (cas 1611-35-4)-based loop-mediated DNA isothermal amplification for sensitive naked-eye detection of Escherichia coli07/21/2019
- Does the gelation temperature or the sulfuric acid concentration influence the dosimetric properties of radiochromic PVA-GTA XYLENOL ORANGE (cas 1611-35-4) Fricke gels?07/19/2019
-
Health and Chemical more >