Iodine X-ray fluorescence computed tomography system utilizing a cadmium telluride detector in conjunction with a cerium-target tube
-
Add time:07/25/2019 Source:sciencedirect.com
An X-ray fluorescence computed tomography system (XRF-CT) is useful for determining the main atoms in objects. To detect iodine atoms without using a synchrotron, we developed an XRF-CT system utilizing a cadmium telluride (CdTe) detector and a cerium X-ray generator. CT is performed by repeated linear scans and rotations of an object. When cerium K-series characteristic X-rays are absorbed by iodine atoms in objects, iodine K fluorescence is produced from atoms and is detected by the CdTe detector. Next, event signals of X-ray photons are produced with the use of charge-sensitive and shaping amplifiers. Iodine Kα fluorescence is isolated using a multichannel analyzer, and the number of photons is counted using a counter card. In energy-dispersive XRF-CT, the tube voltage and tube current were 70 kV and 0.40 mA, respectively, and the X-ray intensity was 115.3 μGy/s at a distance of 1.0 m from the source. The demonstration of XRF-CT was carried out by the selection of photons in an energy range from 27.5 to 29.5 keV with a photon-energy resolution of 1.2 keV.
We also recommend Trading Suppliers and Manufacturers of CERIUM TELLURIDE (cas 12014-97-0). Pls Click Website Link as below: cas 12014-97-0 suppliers
Prev:Structures, properties, and potential applications of rare earth-noble metal tellurides
Next:Simultaneously catalytic decomposition of formaldehyde and ozone over manganese cerium oxides at room temperature: Promotional effect of relative humidity on the MnCeOx solid solution) - 【Back】【Close 】【Print】【Add to favorite 】
- Related Information
- Far infrared properties of PbTe doped with cerium07/30/2019
- Hydroxamic acid interactions with solvated cerium hydroxides in the flotation of monazite and bastnäsite—Experiments and DFT study07/29/2019
- Access to lanthanoid telluride nanoparticles: Liquid exfoliation of LnTe3 (Ln = La, Ho)07/28/2019
- Conventional X-ray fluorescence camera with a cadmium-telluride detector and its application to cancer diagnosis07/27/2019
- Simultaneously catalytic decomposition of formaldehyde and ozone over manganese cerium oxides at room temperature: Promotional effect of relative humidity on the MnCeOx solid solution07/26/2019
- Structures, properties, and potential applications of rare earth-noble metal tellurides07/24/2019
-
Health and Chemical more >