New routes to the preparation of silver-soft liner nanocomposites as an antibacterial agent
-
Add time:08/27/2019 Source:sciencedirect.com
This study evaluated the antimicrobial and physical properties of silver-soft liner nanocomposites (Ag-SLN). Polymerized acrylic soft denture liner disk specimens containing 0 (control), 1500, 3000, or 6000 mg/L of silver nanoparticles were placed on the flat bottom of the separate 12-well cell culture plate dish and 100 μL samples of microbial suspensions of Escherichia coli strain were inoculated on each specimen and incubated at 37 °C, for 24 and or 72 h. The antimicrobial effects were determined according to the number of viable cells in the retrieved suspension. Characterization of silver nanoparticles was carried out based on UV–vis spectroscopy and transmission electron microscopy (TEM) analysis. The specimens were characterized by thermal gravimetric analysis (TGA), field emission scanning electron microscope and energy dispersive X-ray analysis (FE-SEM/EDAX), and atomic absorption spectroscopy (AAS). We successfully prepared Ag-SLN and identified the great excellent antimicrobial activity for E coli.
We also recommend Trading Suppliers and Manufacturers of GC Soft-Liner (cas 113979-65-0). Pls Click Website Link as below: cas 113979-65-0 suppliers
Prev:Original ArticleA study to evaluate the effect of monopoly on the softness of soft liner by durometer
Next:Exploration of environmental contaminants in honeybees using GC-TOF-MS and GC-Orbitrap-MS) - 【Back】【Close 】【Print】【Add to favorite 】
- Related Information
- Evaluation of different adsorbent materials for the untargeted and targeted bacterial VOC analysis using GC×GC-MS09/03/2019
- Aldehydes gas ozonation monitoring: Interest of SIFT/MS versus GC/FID09/02/2019
- Distinguishing drug isomers in the forensic laboratory: GC–VUV in addition to GC–MS for orthogonal selectivity and the use of library match scores as a new source of information09/01/2019
- Review articleSoft denture liners’ effect on the masticatory function in patients wearing complete dentures: A systematic review08/31/2019
- Research and EducationEffect of sealer coating and storage methods on the surface roughness of soft liners08/30/2019
- Tensile bond strengths of silicone soft liners to two chemically different denture base resins08/29/2019
- Exploration of environmental contaminants in honeybees using GC-TOF-MS and GC-Orbitrap-MS08/28/2019
- Original ArticleA study to evaluate the effect of monopoly on the softness of soft liner by durometer08/26/2019
- Full Length ArticleHow to obtain a detailed chemical composition for middle distillates via GC × GC-FID without the need of GC × GC-TOF/MS08/25/2019