Aldehydes gas ozonation monitoring: Interest of SIFT/MS versus GC/FID
-
Add time:09/02/2019 Source:sciencedirect.com
Two analytical techniques – online Gas Chromatography coupled with Flame Ionization Detector (often used method for VOCs monitoring) versus Selected Ion Flow Tube coupled with Mass Spectrometry (a more recent technique based on direct mass spectrometry) – were compared in association to an ozone-based gas treatment. Selecting aldehydes as the representative VOCs, their concentrations were monitored during ozonation experiments by both techniques in parallel. Contradictory results were obtained in the presence of ozone. Aldehydes were up to 90% removed due to a reaction with ozone according to GC/FID analysis, whereas with SIFT/MS, aldehydes concentration remained at the same level during the experiments regardless of the ozone presence. In addition, it was demonstrated that the apparent aldehydes removal was affected by GC injector temperature, varying from 90% (when it was at 250 °C) to 60% (at 100 °C). Meanwhile, even when the ozonation reactor was heated to 100 °C, no aldehydes conversion was evidenced by SIFT/MS, suggesting that the GC injector temperature was not the only interference-causing parameter. The ozone-aldehyde reaction is probably catalyzed by some material of GC injector and/or column. An ozone-GC interference was therefore confirmed, making unsuitable the use of GC/FID with silicone stationary phase to monitor aldehydes in presence of high concentrations of ozone (at least 50 ppmv). On the other hand, SIFT/MS was validated as a reliable technique, which can be employed in order to measure VOCs concentrations in ozonation processes.
We also recommend Trading Suppliers and Manufacturers of GC Soft-Liner (cas 113979-65-0). Pls Click Website Link as below: cas 113979-65-0 suppliers
Prev:Distinguishing drug isomers in the forensic laboratory: GC–VUV in addition to GC–MS for orthogonal selectivity and the use of library match scores as a new source of information
Next:Evaluation of different adsorbent materials for the untargeted and targeted bacterial VOC analysis using GC×GC-MS) - 【Back】【Close 】【Print】【Add to favorite 】
- Related Information
- Evaluation of different adsorbent materials for the untargeted and targeted bacterial VOC analysis using GC×GC-MS09/03/2019
- Distinguishing drug isomers in the forensic laboratory: GC–VUV in addition to GC–MS for orthogonal selectivity and the use of library match scores as a new source of information09/01/2019
- Review articleSoft denture liners’ effect on the masticatory function in patients wearing complete dentures: A systematic review08/31/2019
- Research and EducationEffect of sealer coating and storage methods on the surface roughness of soft liners08/30/2019
- Tensile bond strengths of silicone soft liners to two chemically different denture base resins08/29/2019
- Exploration of environmental contaminants in honeybees using GC-TOF-MS and GC-Orbitrap-MS08/28/2019
- New routes to the preparation of silver-soft liner nanocomposites as an antibacterial agent08/27/2019
- Original ArticleA study to evaluate the effect of monopoly on the softness of soft liner by durometer08/26/2019
- Full Length ArticleHow to obtain a detailed chemical composition for middle distillates via GC × GC-FID without the need of GC × GC-TOF/MS08/25/2019