Evaluation of different adsorbent materials for the untargeted and targeted bacterial VOC analysis using GC×GC-MS
-
Add time:09/03/2019 Source:sciencedirect.com
The analysis of bacterial volatile organic compounds has gained attraction as a non-invasive way to identify disease-causing organisms, given that bacteria have unique metabolisms and volatile metabolic byproducts. In the present research, different adsorbent materials (Carbopack Y, X, B, Carboxen 1000 and Tenax TA), packed singularly or in combination, were compared in terms of sampling performance (sensitivity, repeatability and selectivity) for the extraction of standards and bacterial volatile metabolites in vitro (from Staphylococcus aureus, Pseudomonas aeruginosa, and Escherichia coli). After extraction, bacterial volatile organic compounds were desorbed and analyzed in a comprehensive two-dimensional gas chromatography system coupled to a time-of-flight mass spectrometer (GC × GC-ToF MS).The results show that Tenax has the greater ability to extract the standard mix as well as volatile organic compounds with better repeatability (4–26 RSD%), higher sensitivity (on average ∼24 fold) compared to Carbopack Y, X and Carboxen 1000 tube, which followed in terms of performance. In addition, Tenax confirmed the best sensitivity and discriminatory power with no misclassification in the untargeted and unsupervised analysis for the differentiation of the bacterial species.
We also recommend Trading Suppliers and Manufacturers of GC Soft-Liner (cas 113979-65-0). Pls Click Website Link as below: cas 113979-65-0 suppliers
Prev:Aldehydes gas ozonation monitoring: Interest of SIFT/MS versus GC/FID
Next:Clinical ReportConservative approach to the restoration of vital teeth affected by severe tissue wear) - 【Back】【Close 】【Print】【Add to favorite 】
- Related Information
- Aldehydes gas ozonation monitoring: Interest of SIFT/MS versus GC/FID09/02/2019
- Distinguishing drug isomers in the forensic laboratory: GC–VUV in addition to GC–MS for orthogonal selectivity and the use of library match scores as a new source of information09/01/2019
- Review articleSoft denture liners’ effect on the masticatory function in patients wearing complete dentures: A systematic review08/31/2019
- Research and EducationEffect of sealer coating and storage methods on the surface roughness of soft liners08/30/2019
- Tensile bond strengths of silicone soft liners to two chemically different denture base resins08/29/2019
- Exploration of environmental contaminants in honeybees using GC-TOF-MS and GC-Orbitrap-MS08/28/2019
- New routes to the preparation of silver-soft liner nanocomposites as an antibacterial agent08/27/2019
- Original ArticleA study to evaluate the effect of monopoly on the softness of soft liner by durometer08/26/2019
- Full Length ArticleHow to obtain a detailed chemical composition for middle distillates via GC × GC-FID without the need of GC × GC-TOF/MS08/25/2019


