ChemCatChem
10.1002/cctc.201701416
FULL PAPER
-
1
reduced in flowing hydrogen at 450 °C for 4 h (heating rate: 2 °C∙min
flowing velocity:100 mL∙min ).
,
Acknowledgements
-
1
We acknowledge the financial support from the National Key
Research and Development Program of China (Grant No.
Preparation of copper phyllosilicate by hydrothermal synthesis
Cu/SiO -HT)
A typical Cu/SiO -HS was prepared as follows. Deionized water (140 mL)
was added with Cu(NO ∙3H O, NH Cl, NH ∙H O and a nano sized SiO
2
(
2
2016YFB0701100), the Recruitment Program of Global Young
2
Experts in China, and National Natural Science Foundation of
China (Grant No. 21573075).
3
)
2
2
4
3
2
in order. The solution was stirred for half an hour at ambient temperature,
then dispersed with ultrasonic for half an hour. Afterwards, the mixture
was transferred to a Teflon autoclave (200 mL) and heated to 120 °C
with rotation for 3 h. After the autoclave was cooled to ambient
temperature, the solid was filtered and washed by distilled water several
times. Finally, the solid was dried at 60 °C overnight, calcined in flowing
Keywords: Hydrogen • Methanol composition • Cu-based
Catalysts • Dimethoxylmethane
-
1
air at 450 °C for 4 h (heating rate: 2 °C∙min , flowing velocity:100
-
1
mL∙min ) and reduced in flowing hydrogen at 450 °C for 4 h (heating
-
1
-1
rate: 2 °C∙min , flowing velocity:100 mL∙min ).
References:
Catalyst Characterization
[
1]
P. K. Frolich, M. R. Fenske, D. Quggle, Ind. Eng. Chem., 1928, 20,
694-698.
Cu contents were calculated by data from Inductively coupled plasma
atomic emission spectroscopy (ICP–AES) performed on a Thermo IRIS
Intrepid II XSP emission spectrometer after dissolving the catalyst in the
[2]
[3]
K. Klier, V. Chatikavanu, R. Herman, G. Simmons, J. Catal., 1982, 74,
343-360.
HF solution. N
2
adsorption measurements were carried out at 77 K on a
G. C. Chinchen, P. J. Denny, J. R. Jennings, M. S. Spencer and K. C.
Waugh, Appl. Catal., 1988, 36, 1-65.
BEL-MAX gas/vapor adsorption instrument. The surface areas (and pore
size distribution) were calculated by the Brunauer-Emmett-Teller (BET)
method. Powder X-ray diffraction (XRD) patterns were detected to
confirm the structure and crystal size by Rigaku Ultima IV X-ray
diffractometer utilizing Cu-Kα radiation (λ = 1.5405 Å) operated at 35 kV
and 25 mA. The IR spectra (IR) were collected by Nicolet Nexus 670 FT-
[4]
[5]
[6]
[7]
[8]
[9]
E. M. Calverley, K. T. Smith, J. Catal., 1991, 130, 616-626.
C. Kuechen, U. Hoffman, Chem. Eng. Sci., 1993, 48, 3767-3776.
K. M. V. Bussche, G. F. Froment, Appl. Catal. A: Gen, 1994, 112, 37-55.
W. H. Cheng, Appl. Catal. B: Environ., 1995, 7, 127-136.
W. H. Cheng, Mater. Chem. Phys., 1995, 41, 36-40.
D. Chadwick, K. Zheng, Catal. Lett. 1993, 20, 231-242.
-1
IR spectrometer in absorbance mode at a spectral resolution of 2 cm
using KBr technique. Hydrogen temperature programmed reduction
TPR) were conducted by TP-5080 multi-purpose automatic adsorption
[10] L. Shlegel, D. Gutshik, A. Rozovskii, Kinet. Katal., 1990, 31, 880-882.
[11] W. H. Cheng, Appl. Catal. A: General, 1995, 130, 13-30.
[12] W. H. Cheng, C. Y. Shiau, T. H. Liu, H. L. Tung, J. F. Lu, C.C. Hsu,
Appl. Catal. A: Gen, 1998, 170, 215-224.
(
-
1
instrument by at the ramp rate of 10 K min . Scanning electron
microscopy (SEM) were performed on the Hitachi S-4800 microscope. To
illuminate crystal morphology and size, transmission electron microscopy
[13] J. Xi, Z. Wang, G. Lu. Appl. Catal. A: Gen, 2002, 225, 77-86.
[14] T. P. Minyukova, I. I. Simentsova, A. V. Khasin, N. B. Shtertser, N. A.
Baroskaya, A. A. Khassin, T. M. Yurieva. Appl. Catal. A: Gen, 2002,
237, 171-180.
2
(TEM) images were obtained by the FEI Tecnai G F30 microscope
working at 300 kV. X-ray photoelectron spectroscopy (XPS) were
performed with Al Kα (hν = 1486.6 eV) radiation on a Thermo Scientific
K-Alpha spectrometer. Charging effects were corrected by using the C 1s
peak due to adventitious carbon with EB fixed at 284.6 eV.
[15] L. Domokosa, T. Katonaa, Á. Molnár, A. Lovas, Appl. Catal. A: Gen,
1996, 142, 151-158.
[
[
[
[
16] E. D. Guerreiro, O.F. Gorriz, J.B. Rivarola, L.A. Arrúa, Appl. Catal. A:
Gen, 1997, 165, 259-271.
Catalytic measurements
17] E. D. Guerreiroa, O. F. Gorriz1, G. Larsenc, L. A Arrúab, Appl. Catal. A:
Gen, 2000, 204, 33-48.
A
typical test for producing highly pure hydrogen from methanol
decomposition was carried out as follows: Cu/SiO catalyst (0.1 g) and
methanol (40 mL) were added into a batch autoclave (70 mL). The
reactor was then flushed with N at ambient temperature for three times
to remove the residual air. After evacuating nitrogen, it was heated up to
40 °C. The reaction was conducted for 4 h at a stirring speed of 450
2
18] T. Tsoncheva, R. Nickolov, D. Mehandjiev, React. Kinet. Catal. Lett.,
2001, 72, 383-390.
2
19] T. Tsoncheva, I. Genova, M. Stoyanova, M. Pohlb, R. Nickolovc, M.
Dimitrova, E. Sarcadi-Priboczkid, M. Mihaylove, D. Kovachevae, Appl.
Catal. B: Environ., 2014, 147, 684-697.
2
rpm. After cooling down to ambient temperature, liquid products were
analyzed on a gas chromatograph equipped with a mass spectrometer
[
20] I. A. Fisher and Al. T. Bell. J. Catal., 1999, 184, 357-376.
21] T. Toupance, M. Kermarec, J. F. Lambert, C. Louis, J. Phys. Chem. B
[
(
GC-MS, Shimadzu QP-2010 Ultra) with a Rtx-5Sil MS capillary column
2002, 106, 2277-2286
(30 m×0.25 mm×0.25 μm). Analysis for gaseous products was performed
[22] J. Łojewska, J. Wasilewski, K. Terelak, T. Łojewski, A. Kołodziej, Catal.
Commun., 2008, 9, 1833-1837.
on a GC (Techcomp 7900) equipped with thermal conductivity detector
TCD) and columns (TDX-01: 30 cm×3 mm, TDX-01: 2 m×3 mm), as well
(
[23] L. Wu, L. Li, B. Li, C. Zhao, Chem. Commun., 2017, 53, 6152-6155.
as flame ionization detector (FID) and a HP-PLOT Q capillary column (50
m×0.53 mm×25 μm).
This article is protected by copyright. All rights reserved.