T. R. Sharp et al. / Tetrahedron Letters 44 (2003) 1559–1561
1561
Acknowledgements
detector, equipped with split injection port and electronic
pressure control. The column was a J&W Scientific DB-1
(100% poly(dimethylsiloxane)) bonded phase fused silica
capillary column (30 m×0.25 mm×0.25 m film thickness).
Injector and detector temperatures were set, respectively,
at 250 and 280°C. Oven temperature was held for 2 min
at 100°C, then increased linearly at 5°/min to 240°C, then
held at 240°C for 10 min. Helium carrier gas flow
through the column was approx. 1.3 mL/min (45 cm/s).
Injections were made by autosampler into a split injection
port with split ratio set at 30:1. The mass selective
detector was autotuned and mass calibrated using
perfluorotributylamine (FC-43) according to instrument
manufacturer’s criteria. The detector was operated in
repetitive scan mode, recording full scan mass spectra
from m/z 40 to m/z 450 every 1.9 s.
The authors thank J. A. Lowe III and H. R. Howard
for discussions during preparation of this manuscript.
References
1
2
. Seeger, T. F.; Seymour, P. A.; Schmidt, A. W.; Zorn, S.
H.; Shulz, D. W.; Lebel, L. A.; McLean, S.; Guanowsky,
V.; Howard, H. R.; Lowe, J. A., III; Heym, J. J. Pharma-
col. Expt. Therapeutics 1995, 275, 101–113.
. Howard, H. R.; Lowe, J. A., III; Seeger, T. F.; Seymour,
P. A.; Zorn, S. H.; Maloney, P. R.; Ewing, F. E.;
Newman, M. E.; Schmidt, A. W.; Furman, J. S.;
Robinson, G. L.; Jackson, E.; Johnson, C.; Morrone, J.
J. Med. Chem. 1996, 39, 143–148.
. LC–MS analyses were carried out on a Micromass
Instruments Quattro I triple quadrupole mass spectrome-
ter, coupled to a Hewlett–Packard 1050 modular HPLC
system. Reverse phase separations were carried out on a
Waters Puresil C18 column (4.6 mm×150 mm). Over the
course of a 60 min run, the mobile phase (1 mL/min) was
linearly changed from 10% methanol and 90% aqueous
.1% trifluoroacetic acid to 100% methanol. UV–vis
detection was carried out at 229 nm. The column was
thermostated at 30°C. Column effluent was split approx.
0:1 after passing through the UV–vis detector using a
Valco T-splitter, the smaller portion being presented to
the LC–MS.
. Photochallenge of compounds in solution was conducted
in a Rayonet Model RPR-200 photochemical reaction
chamber with fluorescent lamps. Samples were dissolved
in a mixed solvent of 60% (v/v) methanol and 40%
6
. Porter, Q. N. Mass Spectrometry of Heterocyclic Com-
pounds, 2nd ed.; New York: John Wiley & Sons, 1985;
pp. 896 ff and pp. 906 ff.
3
7
. Diouf, O.; Depreux, P.; Lesieur, D.; Poupaert, J. H.;
Caignard, D. H. Eur. J. Med. Chem. 1995, 30, 715–719.
. Compound 2 was synthesized by reacting one equivalent
of 2-chlorobenzthiazole and the alkylpiperizine derivative
of 6-chlorooxindole in isopropanol. Two equivalents of
triethylamine were added over the course of a ca. 24 h
reflux. The reaction only proceeded to ca. 45% comple-
tion using simple HPLC evaluation. The reaction was
quenched by addition of five equivalents of HCl. The
product was isolated by filtration, washed with iso-
8
0
1
propanol and H O, producing approximately 11% yield
4
2
of a material greater than 95% pure by simple HPLC
evaluation. The reaction was not optimized for yield.
. Maeda, M.; Kojima, M. J. Chem. Soc., Perkin Trans. 1
9
1977, 239–247.
distilled H O, at an initial concentration of 0.2 mg/mL,
2
1
1
0. Goeth, H.; Schmid, H. Chimia 1966, 20, 148.
1. Gilchrist, T. L. Heterocyclic Chemistry; Longman Scien-
tific & Technical Publishers: UK, 1985; p. 214.
and were contained in ordinary Pyrex glass containers.
. GC–MS experiments were conducted on a Hewlett–Pack-
ard 6890 Series gas chromatograph and mass selective
5