Scanning electrochemical microscopy imaging of poly (3,4-ethylendioxythiophene)/thionine electrodes for lactate detection via NADH electrocatalysis
-
Add time:08/03/2019 Source:sciencedirect.com
Herein we report the use of scanning electrochemical microscopy (SECM) together with electrochemical and spectroscopic techniques to develop and characterise a stable and uniformly reactive chemically modified platinum electrode for NADH electrocatalysis. In order to achieve this, a range of different approaches for thionine entrapment within an electropolymerised poly (3,4-ethylendioxythiophene) (PEDOT) film were evaluated using SECM imaging in the presence of NADH, demonstrating the uniformity of the reactive layer towards NADH oxidation. The effect of electrolyte type and time scale employed during PEDOT electropolymerisation was examined with respect to thionine loading and the resulting charge transport diffusion coefficient (DCT) estimated via chronoamperometry. These studies indicated a decrease in DCT as thionine loading increased within the PEDOT film, suggesting that charge transport was diffusion limited within the film. Additionally, thionine functionalised nanotubes were formed, providing a stable support for lactate dehydrogenase entrapment while lowering the rate of thionine leaching, determined via SECM imaging. This enabled lactate determination at Eapp = 0.0 V vs Ag/AgCl over the range 0.25–5 mM in the presence of 1 mM NAD+.
We also recommend Trading Suppliers and Manufacturers of LITHIUM LACTATE (cas 16891-53-5). Pls Click Website Link as below: cas 16891-53-5 suppliers
Prev:LITHIUM LACTATE (cas 16891-53-5) as an ESR dosimeter
Next:Sustained elevation of cerebrospinal fluid glucose and lactate after a single seizure does not parallel with mitochondria energy production) - 【Back】【Close 】【Print】【Add to favorite 】
- Related Information
- Vapour pressures, densities, and viscosities of the (water + lithium bromide + potassium acetate) system and (water + lithium bromide + sodium lactate) system08/11/2019
- The handheld blood lactate analyser versus the blood gas based analyser for measurement of serum lactate and its prognostic significance in severe sepsis08/10/2019
- Plasma lactate measurement as an example of encountered gaps between routine clinical laboratory processes and manufactures' sample-handling instructions08/09/2019
- 1H NMR study of lithium d08/08/2019
- MoS2 nanosheets for improving analytical performance of lactate biosensors08/07/2019
- Performance of synovial fluid D08/06/2019
- One-pot enzymatic synthesis of l08/05/2019
- Sustained elevation of cerebrospinal fluid glucose and lactate after a single seizure does not parallel with mitochondria energy production08/04/2019
- LITHIUM LACTATE (cas 16891-53-5) as an ESR dosimeter08/02/2019
-
Health and Chemical more >