MoS2 nanosheets for improving analytical performance of lactate biosensors
-
Add time:08/07/2019 Source:sciencedirect.com
In this paper, a new 2D lactate electrochemical biosensor was developed. It was based on the incorporation of molybdenum disulfide (MoS2) nanosheets, obtained by an exfoliation method, onto the surface of a glassy carbon (GC) electrode, together with lactate oxidase enzyme (LOx). For the sensor construction, conditions regarding the exfoliation solvent type, as well as both the size and amount of MoS2, were optimized. The biosensor platform (GC/MoS2/LOx) was topographically characterized by atomic force microscopy (AFM) and the charge transfer process occurring at the electrode interface was studied by electrochemical impedance spectroscopy (EIS). The GC/MoS2/LOx biosensor was applied to the determination of lactate in presence of hydroxymethylferrocene (HMF) as a redox mediator. Electrocatalytic effect of the system MoS2/LOx was evaluated by comparing the cyclic voltammetric biosensor response with those obtained for biosensors incorporating only one of the components (MoS2 or LOx) onto the electrode surface. Biosensors containing both components exhibit the best electrocatalytic response. From the calibration curve obtained at +0.30 V, the following analytical parameters were obtained: linear concentration range from 0.056 to 0.77 mM, high sensitivity (6.2 μA mM−1), good detection limit (17 μM) and reproducibility (RSD = 4.7%).
We also recommend Trading Suppliers and Manufacturers of LITHIUM LACTATE (cas 16891-53-5). Pls Click Website Link as below: cas 16891-53-5 suppliers
Prev:Performance of synovial fluid D
Next:1H NMR study of lithium d) - 【Back】【Close 】【Print】【Add to favorite 】
- Related Information
- Vapour pressures, densities, and viscosities of the (water + lithium bromide + potassium acetate) system and (water + lithium bromide + sodium lactate) system08/11/2019
- The handheld blood lactate analyser versus the blood gas based analyser for measurement of serum lactate and its prognostic significance in severe sepsis08/10/2019
- Plasma lactate measurement as an example of encountered gaps between routine clinical laboratory processes and manufactures' sample-handling instructions08/09/2019
- 1H NMR study of lithium d08/08/2019
- Performance of synovial fluid D08/06/2019
- One-pot enzymatic synthesis of l08/05/2019
- Sustained elevation of cerebrospinal fluid glucose and lactate after a single seizure does not parallel with mitochondria energy production08/04/2019
- Scanning electrochemical microscopy imaging of poly (3,4-ethylendioxythiophene)/thionine electrodes for lactate detection via NADH electrocatalysis08/03/2019
- LITHIUM LACTATE (cas 16891-53-5) as an ESR dosimeter08/02/2019
-
Health and Chemical more >