cobinamide (cas 13497-85-3) chemistries for photometric cyanide determination. A merging zone liquid core waveguide cyanide analyzer using cyanoaquacobinamide (cas 13497-85-3)
-
Add time:08/16/2019 Source:sciencedirect.com
Diaquacobinamide (cas 13497-85-3) (H2O)2Cbi2+ or its conjugate base hydroxyaquacobinamide (OH(H2O)Cbi+)) can bind up to two cyanide ions, making dicyanocobinamide. This transition is accompanied by a significant change in color, previously exploited for cyanide determination. The reagent OH(H2O)Cbi+ is used in excess; when trace amounts of cyanide are added, CN(H2O)Cbi+ should be formed. But the spectral absorption of CN(H2O)Cbi+ is virtually the same as that of OH(H2O)Cbi+. It has been inexplicable how trace amounts of cyanide are sensitively measured by this reaction. It is shown here that even with excess OH(H2O)Cbi+, (CN)2Cbi is formed first due to kinetic reasons; this only slowly forms CN(H2O)Cbi+. This understanding implies that CN(H2O)Cbi+ will itself be a better reagent.We describe a single valve merging zone flow analyzer that allows both sample and reagent economy. With a 50 cm liquid core waveguide (LCW) flow cell and an inexpensive fiber optic – charge coupled device array spectrometer, a S/N = 3 limit of detection of 8 nM, a linear dynamic range to 6 μM, and excellent precision (RSD 0.49% and 1.07% at 50 and 100 nM, respectively, n = 5 each) are formed. At 1% carryover, sample throughput is 40 h−1. The setup is readily used to measure thiocyanate with different reagents. We demonstrate applicability to real samples by analyzing human saliva samples and hydrolyzed extracts of apple seeds, peach pits, and almonds.
We also recommend Trading Suppliers and Manufacturers of cobinamide (cas 13497-85-3). Pls Click Website Link as below: cas 13497-85-3 suppliers
Prev:Simultaneous determination of 3-mercaptopyruvate and cobinamide (cas 13497-85-3) in plasma by liquid chromatography–tandem mass spectrometry
Next:Development of a cobinamide (cas 13497-85-3)-based end-of-service-life indicator for detection of hydrogen cyanide gas) - 【Back】【Close 】【Print】【Add to favorite 】
- Related Information
- Development of a cobinamide (cas 13497-85-3)-based end-of-service-life indicator for detection of hydrogen cyanide gas08/17/2019
- Simultaneous determination of 3-mercaptopyruvate and cobinamide (cas 13497-85-3) in plasma by liquid chromatography–tandem mass spectrometry08/15/2019
- Intramuscular cobinamide (cas 13497-85-3) Sulfite in a Rabbit Model of Sublethal Cyanide Toxicity08/14/2019
- Intravenous cobinamide (cas 13497-85-3) Versus Hydroxocobalamin for Acute Treatment of Severe Cyanide Poisoning in a Swine (Sus scrofa) Model08/13/2019
- Inhibition of nitric oxide synthase by cobalamins and cobinamide (cas 13497-85-3)s08/12/2019
- High performance liquid chromatography tandem mass spectrometry assay for the determination of cobinamide (cas 13497-85-3) in pig plasma08/11/2019
- Comparative study of reaction of cobalamin and cobinamide (cas 13497-85-3) with thiocyanate08/10/2019
- Determination of free cyano-cobinamide (cas 13497-85-3) in swine and rabbit plasma by liquid chromatography tandem mass spectrometry08/09/2019
- Mechanistic basis of vitamin B12 and cobinamide (cas 13497-85-3) salvaging by the Vibrio species08/08/2019