Development of a cobinamide (cas 13497-85-3)-based end-of-service-life indicator for detection of hydrogen cyanide gas
-
Add time:08/17/2019 Source:sciencedirect.com
We describe an inexpensive paper-based sensor for rapid detection of low concentrations (ppm) of hydrogen cyanide gas. A piece of filter paper pre-spotted with a dilute monocyanocobinamide [CN(H2O)Cbi] solution was placed on the end of a bifurcated optical fiber and the reflectance spectrum of the CN(H2O)Cbi was monitored during exposure to 1.0–10.0 ppm hydrogen cyanide gas. Formation of dicyanocobinamide yielded a peak at 583 nm with a simultaneous decrease in reflectance from 450–500 nm. Spectral changes were monitored as a function of time at several relative humidity values: 25, 50, and 85% relative humidity. With either cellulose or glass fiber papers, spectral changes occurred within 10 s of exposure to 5.0 ppm hydrogen cyanide gas (NIOSH recommended short-term exposure limit). We conclude that this sensor could provide a real-time end-of-service-life alert to a respirator user.
We also recommend Trading Suppliers and Manufacturers of cobinamide (cas 13497-85-3). Pls Click Website Link as below: cas 13497-85-3 suppliers
Prev:cobinamide (cas 13497-85-3) chemistries for photometric cyanide determination. A merging zone liquid core waveguide cyanide analyzer using cyanoaquacobinamide (cas 13497-85-3)
Next:Thermal analysis of activated carbons modified with SILVER METAVANADATE (cas 13497-94-4)) - 【Back】【Close 】【Print】【Add to favorite 】
- Related Information
- cobinamide (cas 13497-85-3) chemistries for photometric cyanide determination. A merging zone liquid core waveguide cyanide analyzer using cyanoaquacobinamide (cas 13497-85-3)08/16/2019
- Simultaneous determination of 3-mercaptopyruvate and cobinamide (cas 13497-85-3) in plasma by liquid chromatography–tandem mass spectrometry08/15/2019
- Intramuscular cobinamide (cas 13497-85-3) Sulfite in a Rabbit Model of Sublethal Cyanide Toxicity08/14/2019
- Intravenous cobinamide (cas 13497-85-3) Versus Hydroxocobalamin for Acute Treatment of Severe Cyanide Poisoning in a Swine (Sus scrofa) Model08/13/2019
- Inhibition of nitric oxide synthase by cobalamins and cobinamide (cas 13497-85-3)s08/12/2019
- High performance liquid chromatography tandem mass spectrometry assay for the determination of cobinamide (cas 13497-85-3) in pig plasma08/11/2019
- Comparative study of reaction of cobalamin and cobinamide (cas 13497-85-3) with thiocyanate08/10/2019
- Determination of free cyano-cobinamide (cas 13497-85-3) in swine and rabbit plasma by liquid chromatography tandem mass spectrometry08/09/2019
- Mechanistic basis of vitamin B12 and cobinamide (cas 13497-85-3) salvaging by the Vibrio species08/08/2019


