Development of a nickel plated aluminum Krypton-81m (cas 15678-91-8) target system
-
Add time:09/01/2019 Source:sciencedirect.com
A fully automated system was developed to produce rubidium-81 (81Rb), based on the natKr (p, n) 81Rb reaction. The energy incident on the target was 26 MeV. Only 6 MeV was stopped inside the gas and the remainder was stopped by a specially designed flange. The target body was characterized by its conical shape and its inner walls were chemically plated with 100±10 µm of nickel (Ni). Ni is advantageous as a fairly good conductor of heat whose surface can resist solutions. Additionally, the Ni plated target allowed potassium chloride to dissolve 81Rb, with no further effect on the target body. The system produced 81Rb with a production yield of approximately 4.5 mCi/µA h, which is close to the calculated expected yield of 5.3 mCi/µA h. The system is able to deliver reliable and reproducible radioactivity for patients and can be operated up to 1500 µA h before preventive maintenance is due. Key steps in designing the 81Rb target for selected energy ranges are reported here.
We also recommend Trading Suppliers and Manufacturers of Krypton-81m (cas 15678-91-8). Pls Click Website Link as below: cas 15678-91-8 suppliers
Prev:Cascade synthesis of the first imidazo[4,5-e]-thiazolo[2,3-c][1,2,4]triazine derivative
Next:MethodAssessment of coronary venous bypass graft function using Krypton-81m (cas 15678-91-8)☆) - 【Back】【Close 】【Print】【Add to favorite 】
- Related Information
- Experimental validation of a new coronary guide wire labeled with rubidium 81/krypton 81m for continuous assessment of myocardial blood flow09/08/2019
- MethodDefinition of myocardial perfusion by continuous infusion of Krypton-81m (cas 15678-91-8)☆09/07/2019
- MethodKrypton-81m (cas 15678-91-8) in the physiologic assessment of coronary arterial stenosis in man☆09/06/2019
- Right ventricular ejection fraction measured by first-pass intravenous Krypton-81m (cas 15678-91-8): Reproducibility and comparison with technetium-99m☆09/05/2019
- Continuous determination of regional myocardial blood flow with intracoronary Krypton-81m (cas 15678-91-8) in coronary artery disease☆09/04/2019
- Original investigationCoregistered Ventilation and Perfusion SPECT Using Krypton-81m (cas 15678-91-8) and Tc-99m−Labeled Macroaggregated Albumin With Multislice CT: Utility for Prediction of Postoperative Lung Function in Non−Small Cell Lung Cancer Patients09/03/2019
- MethodAssessment of coronary venous bypass graft function using Krypton-81m (cas 15678-91-8)☆09/02/2019