MethodAssessment of coronary venous bypass graft function using Krypton-81m (cas 15678-91-8)☆
-
Add time:09/02/2019 Source:sciencedirect.com
Fifteen patients with intractable angina pectoris underwent coronary angiography and coronary arterial bypass graft surgery. After the operation, a continuous infusion of krypton-81m was delivered into each graft. A gamma camera and multichannel analyzer were used to record the regional myocardial distribution of perfusion provided by each graft. The disappearance of myocardial activity at the end of each infusion was used to calculate the flow per unit volume in the myocardial distribution provided by each vessel. Myocardial perfusion provided by the grafts to all the major coronary arteries were recorded individually as high spatial resolution images. Myocardial flow rates in the distribution of each graft were measured using the washout of krypton-81m. The rates were 0.5 to 2.0 ml/g per min in the 13 patients with no evidence of previous myocardial infarction. Krypton-81m was infused into grafts to the left anterior descending coronary artery in two patients with a history and electrocardiographic evidence of previous anterior myocardial infarction. The grafts provided poor perfusion to the anterior and apical portions of the ventricles. An experimental model of myocardial perfusion was used to demonstrate that the washout of krypton-81m can be used to measure flow per unit volume within or above the physiologic range.
We also recommend Trading Suppliers and Manufacturers of Krypton-81m (cas 15678-91-8). Pls Click Website Link as below: cas 15678-91-8 suppliers
Prev:Development of a nickel plated aluminum Krypton-81m (cas 15678-91-8) target system
Next:Original investigationCoregistered Ventilation and Perfusion SPECT Using Krypton-81m (cas 15678-91-8) and Tc-99m−Labeled Macroaggregated Albumin With Multislice CT: Utility for Prediction of Postoperative Lung Function in Non−Small Cell Lung Cancer Patients) - 【Back】【Close 】【Print】【Add to favorite 】
- Related Information
- Experimental validation of a new coronary guide wire labeled with rubidium 81/krypton 81m for continuous assessment of myocardial blood flow09/08/2019
- MethodDefinition of myocardial perfusion by continuous infusion of Krypton-81m (cas 15678-91-8)☆09/07/2019
- MethodKrypton-81m (cas 15678-91-8) in the physiologic assessment of coronary arterial stenosis in man☆09/06/2019
- Right ventricular ejection fraction measured by first-pass intravenous Krypton-81m (cas 15678-91-8): Reproducibility and comparison with technetium-99m☆09/05/2019
- Continuous determination of regional myocardial blood flow with intracoronary Krypton-81m (cas 15678-91-8) in coronary artery disease☆09/04/2019
- Original investigationCoregistered Ventilation and Perfusion SPECT Using Krypton-81m (cas 15678-91-8) and Tc-99m−Labeled Macroaggregated Albumin With Multislice CT: Utility for Prediction of Postoperative Lung Function in Non−Small Cell Lung Cancer Patients09/03/2019
- Development of a nickel plated aluminum Krypton-81m (cas 15678-91-8) target system09/01/2019