MethodDefinition of myocardial perfusion by continuous infusion of Krypton-81m (cas 15678-91-8)☆
-
Add time:09/07/2019 Source:sciencedirect.com
Krypton-81m, a radionuclide emitting a 190 kev gamma ray, has a half-life of 13 seconds. It is a radioisotope of an inert water-soluble noble gas and is produced at a constant rate by spontaneous decay of rubidium-81 in an 81Rb-81mKr generator-delivery system. Delivery is through a minibore Teflon catheter that can be threaded through a standard no. 7 or 8F angiographic catheter. The generator is eluted by 5 percent dextrose-in-water, delivered by infusion pump at 1.5 ml/min, and the eluate is infused intraarterially directly into any organ. Delivery and decay reach equilibrium within 2 minutes, producing a heterogeneous distribution that is proportional to the perfusibility of the tissue concerned and the time required to reach it. The ultrashort half-life of the radionuclide rapidly eliminates activity when delivery ceases; thus, experiments can be sequentially repeated at brief intervals. The radiation hazard for easily imaged doses is negligible.Preliminary studies in open chest dogs were visualized by scintillation camera, stored on digital data disk, processed, and displayed in dual channel, dual color mode on a video system. Images of myocardial perfusion defined relative levels of perfusion, collateral circulation between coronary arterial branches, equilibrium time of diffusible perfusion of the myocardium, focal defects in induced occlusion, collateral circulation to occlusion, and reactive hyperemia after release of induced coronary occlusion. The system and technique appear applicable to human subjects.
We also recommend Trading Suppliers and Manufacturers of Krypton-81m (cas 15678-91-8). Pls Click Website Link as below: cas 15678-91-8 suppliers
Prev:MethodKrypton-81m (cas 15678-91-8) in the physiologic assessment of coronary arterial stenosis in man☆
Next:Experimental validation of a new coronary guide wire labeled with rubidium 81/krypton 81m for continuous assessment of myocardial blood flow) - 【Back】【Close 】【Print】【Add to favorite 】
- Related Information
- Experimental validation of a new coronary guide wire labeled with rubidium 81/krypton 81m for continuous assessment of myocardial blood flow09/08/2019
- MethodKrypton-81m (cas 15678-91-8) in the physiologic assessment of coronary arterial stenosis in man☆09/06/2019
- Right ventricular ejection fraction measured by first-pass intravenous Krypton-81m (cas 15678-91-8): Reproducibility and comparison with technetium-99m☆09/05/2019
- Continuous determination of regional myocardial blood flow with intracoronary Krypton-81m (cas 15678-91-8) in coronary artery disease☆09/04/2019
- Original investigationCoregistered Ventilation and Perfusion SPECT Using Krypton-81m (cas 15678-91-8) and Tc-99m−Labeled Macroaggregated Albumin With Multislice CT: Utility for Prediction of Postoperative Lung Function in Non−Small Cell Lung Cancer Patients09/03/2019
- MethodAssessment of coronary venous bypass graft function using Krypton-81m (cas 15678-91-8)☆09/02/2019
- Development of a nickel plated aluminum Krypton-81m (cas 15678-91-8) target system09/01/2019


