Right ventricular ejection fraction measured by first-pass intravenous Krypton-81m (cas 15678-91-8): Reproducibility and comparison with technetium-99m☆
-
Add time:09/05/2019 Source:sciencedirect.com
Study of the effects of various diseases and therapeutic manipulation of pulmonary vascular resistance on the right ventricle has been restricted by methodologic limitations. The radioactive gas in solution, krypton-81m was used to study the right ventricle and the technique was compared with a technetium-99m method. In 22 subjects, first-pass krypton-81m right ventricular ejection fraction, acquired both in list mode and electrocardiogramgated frame mode, correlated well (r = 0.81 and 0.86, respectively, p < 0.01) with that determined by technetium-99m first-pass studies over a broad range of ventricular function. The reproducibility of the technique was excellent (r = 0.84 and 0.95 for each acquisition mode, respectively). Krypton-81m first-pass studies provide accurate and reproducible estimates of right ventricular function. Use of krypton allows multiple measurements, with or without perturbations, over a short period of time.
We also recommend Trading Suppliers and Manufacturers of Krypton-81m (cas 15678-91-8). Pls Click Website Link as below: cas 15678-91-8 suppliers
Prev:Continuous determination of regional myocardial blood flow with intracoronary Krypton-81m (cas 15678-91-8) in coronary artery disease☆
Next:MethodKrypton-81m (cas 15678-91-8) in the physiologic assessment of coronary arterial stenosis in man☆) - 【Back】【Close 】【Print】【Add to favorite 】
- Related Information
- Experimental validation of a new coronary guide wire labeled with rubidium 81/krypton 81m for continuous assessment of myocardial blood flow09/08/2019
- MethodDefinition of myocardial perfusion by continuous infusion of Krypton-81m (cas 15678-91-8)☆09/07/2019
- MethodKrypton-81m (cas 15678-91-8) in the physiologic assessment of coronary arterial stenosis in man☆09/06/2019
- Continuous determination of regional myocardial blood flow with intracoronary Krypton-81m (cas 15678-91-8) in coronary artery disease☆09/04/2019
- Original investigationCoregistered Ventilation and Perfusion SPECT Using Krypton-81m (cas 15678-91-8) and Tc-99m−Labeled Macroaggregated Albumin With Multislice CT: Utility for Prediction of Postoperative Lung Function in Non−Small Cell Lung Cancer Patients09/03/2019
- MethodAssessment of coronary venous bypass graft function using Krypton-81m (cas 15678-91-8)☆09/02/2019
- Development of a nickel plated aluminum Krypton-81m (cas 15678-91-8) target system09/01/2019


