Journal of Materials Chemistry B p. 4640 - 4652 (2014)
Update date:2022-08-30
Topics:
Barran-Berdon, Ana L.
Misra, Santosh K.
Datta, Sougata
Munoz-Ubeda, Monica
Kondaiah, Paturu
Junquera, Elena
Bhattacharya, Santanu
Aicart, Emilio
Lipoplex nano-aggregates have been analyzed through biophysical characterization (electrostatics, structure, size and morphology), and biological studies (transfection efficiency and cell viability) in five cancer cell lines. Lipoplexes were prepared from pEGFP-C3 plasmid DNA (pDNA) and mixed liposomes, constituted by a zwitterionic lipid (DOPE) and a gemini cationic lipid (GCL) synthesized in this work, [bis(hexadecyl dimethyl ammonium) oxyethylene], referred to as (C16Am)2(C2O) n, (where n is the oxyethylene spacer length, n = 1, 2 or 3, between the ammonium heads). Cryo-TEM micrographs show nano-aggregates with two multilamellar structures, a cluster-type (at low-to-medium GCL composition) and a fingerprint-type that coexists with the cluster-type at medium GCL composition and appears alone at high GCL composition. SAXS diffractograms show that these lipoplexes present three lamellar structures, two of them coexisting at low and high GCL composition. The optimized transfection efficiency (TE) of pDNA was higher for lipoplexes containing GCLs with a longer (n = 3) or shorter (n = 1) polyoxyethylene spacer, at high GCL composition (α = 0.7) with low charge ratio (ρeff = 2). In the all cancer cell lines studied, the TE of the optimized formulations was much better than those of both lipofectamine 2000 and lipoplexes with GCLs of the bis(hexadecyl dimethyl ammonium) alkane series recently reported. Probably, (a) the coexistence of two lamellar structures at high GCL composition synergizes the TE of these lipid vectors, (b) the orientation of the polyoxyethylene region in (C16Am) 2(C2O)3/DOPE may occur in such a way that the spacing between two cationic heads becomes smaller than that in (C 16Am)2(C2O)2/DOPE which is poor in terms of TE, and (c) the synergistic interactions between serum proteins and (C16Am)2(C2O)n/DOPE-pDNA lipoplexes containing a polyoxyethylene spacer improve TE, especially at high GCL content. Lipoplexes studied here show very low levels of toxicity, which confirm them as improved vectors of pDNA in gene therapy.
View MoreChengdu Pukang Biotechnology Co., Ltd
website:http://www.pu-kang.com
Contact:86-028-63976226
Address:No. 868 Xiwang Road,Xinjin county,Chengdu city, China
Geen Chemical Technology Co., Ltd
Contact:86-769-21660847
Address:1408, Yingfeng Commercial Center, Nancheng District
Nanjing Legend Pharmaceutical & Chemical Co., Ltd.
Contact:+86-25-83767696
Address:14-7 Zhongshan Lu Guluo District, Nanjing
Hunan Zhongqi Pharmaceutical Co., Ltd
website:http://www.hnzqzy.com
Contact:0730-8722288 13807308622
Address:Wanjiafan Road ,Yueyang Economic And Technological Development Zone ,Hunan,PRC
Jiaxing Trustworthy Import And Export Co.,Ltd
Contact:+86-573-82030555
Address:Room 1202, Unit B, Charming plaza,No.1558 East Zhongshan Road , Jiaxing City, Zhejiang Province, China.
Doi:10.1021/ja01308a508
(1935)Doi:10.1016/j.chempr.2020.04.007
(2020)Doi:10.1007/BF00954022
(1986)Doi:10.1016/S1040-6190(01)00221-4
()Doi:10.1039/CT9232300133
(1923)Doi:10.7164/antibiotics.26.284
(1973)