New microdialysis-electrochemical device for simultaneous determination of ascorbic acid and 5-HYDROXYINDOLE-3-ACETIC ACID (cas 1321-73-9) in rat striatum
-
Add time:08/20/2019 Source:sciencedirect.com
A new device combining microdialysis with electrochemical microsensor was developed. It can be applied to monitor the biomolecules in the brain for biological and pharmaceutical research. In this paper, the device was applied to simultaneously determine ascorbic acid (AA) and 5-HYDROXYINDOLE-3-ACETIC ACID (cas 1321-73-9) (5-HIAA) in rat striatum. The microsensor used for the device was poly (sulphosalicylic acid) microsensor, which exhibited a good electrocatalytic effect on oxidization of AA and 5-HIAA. The oxidation currents measured by differential pulse voltammetry (DPV) were linear for AA in the range of 0.02–1.0 mmol l−1, and for 5-HIAA from 0.5 to 10.0 μmol l−1 (r=0.9998 and 0.9991, respectively). The detection limits were calculated to be 0.01 mmol l−1 for AA and 0.25 μmol l−1for 5-HIAA (S/N=3). Studies also showed that co-existing substances in biological fluids did not interfere with AA and 5-HIAA determination when using this microsensor. Since, the substances in the microdialysate are easily oxidized by air, the microdialysate in this device was under the protection of N2. It was found that the concentrations of AA and 5-HIAA in rat striatum were 215±5 and 6.21±0.61 μmol l−1 (mean±S.E.M., n=7), respectively with this device under the protection of N2. In addition, the effect of the nitric oxide donor, sodium nitroprusside (SNP), on 5-HIAA in the rat striatum was investigated. It was found that a high concentration of SNP (1.0 mmol l−1) resulted in a 34% increase in 5-HIAA level.
We also recommend Trading Suppliers and Manufacturers of 5-HYDROXYINDOLE-3-ACETIC ACID (cas 1321-73-9). Pls Click Website Link as below: cas 1321-73-9 suppliers
Prev:ArticleThe Urinary Ratio of 5-Hydroxytryptophol to 5-HYDROXYINDOLE-3-ACETIC ACID (cas 1321-73-9) in Surgical Patients with Chronic Alcohol Misuse
Next:Assay of urinary 5-HYDROXYINDOLE-3-ACETIC ACID (cas 1321-73-9): two methodologies compared) - 【Back】【Close 】【Print】【Add to favorite 】
- Related Information
- Simultaneous determination of norepinephrine, serotonin, and 5-HYDROXYINDOLE-3-ACETIC ACID (cas 1321-73-9) in microdialysis samples from rat brain by microbore column liquid chromatography with fluorescence detection following derivatization with benzylamine08/26/2019
- Urinary excretion patterns of 5-HYDROXYINDOLE-3-ACETIC ACID (cas 1321-73-9) and 5-hydroxytryptophol in various animal species: Implications for studies on serotonin metabolism and turnover rate08/25/2019
- Urinary excretion of 5-HYDROXYINDOLE-3-ACETIC ACID (cas 1321-73-9) and 5-hydroxytryptophol after oral loading with serotonin08/24/2019
- Simple and rapid determination of 5-HYDROXYINDOLE-3-ACETIC ACID (cas 1321-73-9) in urine by direct injection on a liquid chromatographic column08/23/2019
- Sensitive determination of deuterated and non-deuterated indole-3-acetic acid and 5-HYDROXYINDOLE-3-ACETIC ACID (cas 1321-73-9) by combined capillary gas chromatography—negative-ion chemical ionization mass spectrometry08/22/2019
- Assay of urinary 5-HYDROXYINDOLE-3-ACETIC ACID (cas 1321-73-9): two methodologies compared08/21/2019
- ArticleThe Urinary Ratio of 5-Hydroxytryptophol to 5-HYDROXYINDOLE-3-ACETIC ACID (cas 1321-73-9) in Surgical Patients with Chronic Alcohol Misuse08/19/2019
- Photo-activated 5-HYDROXYINDOLE-3-ACETIC ACID (cas 1321-73-9) induces apoptosis of prostate and bladder cancer cells08/18/2019
- Artificial enzyme-based catalytic sensor for the electrochemical detection of 5-HYDROXYINDOLE-3-ACETIC ACID (cas 1321-73-9) tumor marker in urine08/17/2019
-
Health and Chemical more >


