N. Zientek et al.
[2] M. Maiwald, O. Steinhof, C. J. Sleigh, M. A. Bernstein, H. Hasse, in NMR
Spectroscopy in Pharmaceutical Analysis (Eds: I. Wawer, B. Diehl, U.
Holzgrabe), Elsevier, Amsterdam, 2008, pp. 471–491. DOI: 10.1016/
B978-0-444-53173-5.00020-2
[3] L. F. Gladden. Chem. Eng. J. 1995, 56, 149–158. doi:10.1016/B978-0-444-
53173-5.00020-2.
Table 1. Comparison of root-mean-square errors (RMSEs) calculated by
using line fit-derived data from 1H HR-NMR as a reference for predicted
data by the tested approaches
1H MR-NMR
19F MR-NMR
TFE
AA
TFEA
TFE
TFEA
[4] G. F. Pauli, T. Gödecke, B. U. Jaki, D. C. Lankin. J. Nat. Prod. 2012, 75(4),
834–851. doi:10.1021/np200993k.
(mol lꢀ1
)
(mol lꢀ1
)
(mol lꢀ1
)
(mol lꢀ1
)
(mol lꢀ1
)
[5] S. K. Bharti, R. Roy. Trends Anal. Chem. 2012, 35, 5–26. doi:10.1016/j.
trac.2012.02.007.
[6] J. F. Haw, T. E. Glass, H. C. Dorn. J. Magn. Reson. 1982, 49, 22–31.
doi:10.1016/0022-2364(82)90292-X.
[7] G. Maniara, K. Rajamoorthi, S. Rajan, G. W. Stockton. Anal. Chem. 1998,
70, 4921–4928. doi:10.1021/ac980573i.
DI
0.190
0.153
0.155
0.058
0.143
0.105
0.075
0.061
0.183
0.264
0.170
0.114
0.286
0.622
0.517
0.702
0.171
0.249
5.350
5.543
LF
IHM
PLS-R
[8] T. Nakayama, Y. Fujiwara. Anal. Chem. 1982, 54, 25–28. doi:10.1021/
ac00238a010.
[9] A. M. Wolters, D. A. Jayawickrama, C. K. Larive, J. V. Sweedler. Anal.
Chem. 2002, 74, 4191–4197. doi:10.1021/ac025585p.
[10] M. Maiwald, H. H. Fischer, Y.-K. Kim, H. Hasse. Anal. Bioanal. Chem. 2003,
375, 1111–1115. doi:10.1007/s00216-002-1723-y.
[11] M. A. Bernstein, M. Stefinovic, C. J. Sleigh. Magn. Res. Chem. 2007, 45,
564–571. doi:10.1021/ac100110m.
which affect line form and position, have to be included into the
models by suitable calibration measurements. When these precon-
ditions are not met, prediction results may suffer from high uncer-
tainties. A typical approach to circumvent this problem is binning.[23]
[12] M. Khajeh, A. Botana, M. A. Bernstein, M. Nilsson, G. A. Morris. Anal.
Chem. 2010, 82, 2102–2108. doi:10.1021/ac100110m.
[13] D. A. Foley, C. W. Doecke, J. Y. Buser, J. M. Merritt, L. Murphy, M. Kissane,
S. G. Collins, A. R. Maguire, A. Kaerner. J. Org. Chem. 2011, 76,
9630–9640. doi:10.1021/jo201212p.
[14] J. M. Merritt, J. Y. Buser, A. N. Campbell, J. W. Fennell, N. J. Kallman,
T. M. Koenig, H. Moursy, M. A. Pietz, N. Scully, U. K. Singh. Org. Process
Res. Dev. 2013, 18, 246–256. doi:10.1021/op400226m.
[15] T. W. Skloss, A. J. Kim, J. F. Haw. Anal. Chem. 1994, 66, 536–542.
doi:10.1021/ac00076a019.
[16] C. A. McGill, A. Nordon, D. Littlejohn. Analyst 2002, 127, 287–292.
doi:10.1039/B106889J.
[17] A. Nordon, C. Meunier, R. H. Carr, P. J. Gemperline, D. Littlejohn. Anal.
Chim. Acta 2002, 472, 133–140. DOI: 10.1016/S0003-2670(02)00939-X
[18] A. Nordon, C. A. McGill, D. Littlejohn. Appl. Spectrosc. 2002, 56, 75–82.
doi:10.1366/0003702021954241.
[19] F. Dalitz, M. Cudaj, M. Maiwald, G. Guthausen. Prog. Nucl. Magn. Reson.
Spectrosc. 2012, 60, 52–70. doi:10.1016/j.pnmrs.2011.11.003.
[20] S. S. Zalesskiy, E. Danieli, B. Blümich, V. P. Ananikov. Chem. Rev. 2014,
114, 5641–5694. doi:10.1021/cr400063g.
[21] N. Zientek, C. Laurain, K. Meyer, M. Kraume, G. Guthausen, M. Maiwald.
J. Magn. Reson. 2014, in press. DOI: 10.1016/j.jmr.2014.10.007
[22] E. Kriesten, F. Alsmeyer, A. Bardow, W. Marquardt. Chemometr. Intell.
Lab. 2008, 91, 181–193. doi:10.1016/j.chemolab.2007.11.004.
[23] E. Kriesten, D. Mayer, F. Alsmeyer, C. B. Minnich, L. Greiner,
W. Marquardt. Chemometr. Intell. Lab. 2008, 93, 108–119. doi:10.1016/
j.chemolab.2008.05.002.
Conclusion and outlook
Diverse data processing strategies are known in NMR. Four out of
this variety of mathematical approaches were applied on data ob-
tained during a sample esterification reaction by HR-NMR and
MR-NMR spectroscopy. Similar results in terms of concentrations
were obtained that reflect the reaction progress consistently. All
data analysis methods in general and especially chemometric
models require a constant signal quality over the duration of the ex-
periment, i.e. line shape, symmetry and ideally Gaussian–Lorentzian
shape. Finally, it turns out that the instrumental stability and robust-
ness against environmental influences are important prerequisites
for a successful data analysis and even more important than the
highest potential dispersion, especially in the case of PLS-R. In the
case of IHM, potential developments include the implementation
of prior knowledge of the multiplet structure, flexible line shape
functions and an improvement of the optimisation algorithm. Sim-
ilar arguments hold for the line fitting approach. Line shifts pose
problems and are addressed by suitable line alignment algorithms.
Overlap of lines poses problems especially to DI and to a smaller ex-
tent on line fitting, in which cases IHM and PLS-R can successfully
be applied. A unified data structure, not only for the raw data but
also for switching between modular data preparation and data
analysis tools, is preferable for future developments because it
smoothes the way for automated applications.
[24] T. M. Alam, M. K. Alam. Ann. Rep. NMR Spectrosc. 2005, 54, 41–80.
doi:10.1016/S0066-4103(04)54002-4.
[25] G. Guthausen, A. Garnier, R. Reimert. Appl. Spectrosc. 2009, 63,
1121–1127. doi:10.1366/000370209789553156.
[26] F. Dalitz, L. Kreckel, M. Maiwald, G. Guthausen. Appl. Magn. Reson. 2014,
45, 411–425. doi:10.1007/s00723-014-0522-x.
[28] L. Chen, Z. Weng, L. Goh, M. Garland. J. Magn. Reson. 2002, 158,
164–168. doi:10.1016/S1090-7807(02)00069-1.
[29] F. Alsmeyer, H.-J. Koß, W. Marquardt. J. Appl. Spectrosc. 2004, 58(8),
975–986. doi:10.1366/0003702041655368.
[30] F. Alsmeyer, W. Marquardt. Appl. Spectrosc. 2004, 58(8), 986–994.
doi:10.1366/0003702041655421.
Acknowledgements
The authors acknowledge support from Deutsche Forschungs-
gemeinschaft by projects MA 2292/1-1 and GU1123/2-1. Helpful
discussions with Clemens Minnich are also gratefully acknowl-
edged. The authors thank Magritek (Germany and New Zeeland)
for the straightforward support. Further, helpful discussions with
Franz Dalitz are gratefully acknowledged. MM wants to thank Ulrich
Panne for supporting this project. GG also thanks the Deutsche
Forschungsgemeinschaft for financial support of the instrumental
facility Pro2NMR.
[31] N. M. Faber, R. Rajkó. Anal. Chim. Acta 2007, 595, 98–106. doi:10.1016/j.
aca.2007.05.030.
[32] W. Kessler, Multivariate Datenanalyse: für die Pharma-, Bio- und
Prozessanalytik,
Wiley-VCH,
Weinheim,
2007.
doi:10.1002/
9783527610037.
Supporting information
References
Additional supporting information may be found in the online ver-
sion of this article at the publisher’s web site.
[1] M. Maiwald, H. H. Fischer, Y. K. Kim, K. Albert, H. Hasse. J. Magn. Reson.
2004, 166, 135–146. doi:10.1016/j.jmr.2003.09.003.
wileyonlinelibrary.com/journal/mrc
Copyright © 2015 John Wiley & Sons, Ltd.
Magn. Reson. Chem. (2015)